JUMO Logo
  • Team Sales

    Technical consulting & individual offers

    +33 3 87 37 53 00
    automation
    +33 3 87 37 53 00
    sensors
    Hotline

    Troubleshooting

    0892 700 733 (cost 0,80€ TTC/minute)
    Support
    Team Engineering

    Individual products developments & innovations

    +33 3 87 37 53 44
    Engineering
    • Germany
      • German
      • English
    • Switzerland
      • German
      • English
    • Poland
      • Polish
      • English
    • Netherlands
      • Dutch
      • English
    • Sweden
      • Swedish
      • English
    • Belgium
      • Dutch
      • French
      • German
      • English
    • France
      • French
      • English
    • Austria
      • German
      • English
    • Spain
      • Spanish
      • English
    • Italy
      • Italian
      • English
    • Slovenia
      • English
    • Croatia
      • English
    • Serbia
      • English
    • Bosnia
      • English
    • Hungaria
      • English
    • USA
      • English
    • United Kingdom
      • English
    • Czech Republic
      • Czech
      • English
  • 0
  • Search for

    Are you looking for suitable products for a specific application? Start product selection guide

  • Products
    • Catalogue standard FR
    • Product Highlights
    • Stock Catalogue
    • Temperature
      • Automation
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Platinum temperature sensors Pt100, Pt1000
      • Controllers
      • Switches
      • Thermocouples
      • Thermostats
      • Monitors & limiters
      • Heat meters
      • RTD temperature probes
      • Dial thermometers
      • Contact dial thermometers
      • Accessories
    • Liquid analysis
      • Automation system
      • Electrodes & Sensors
      • Transmitter & Controllers
      • Accessories
    • Pressure
      • Automation system
      • Digital indicators
      • Transmitters
      • Measuring cells
      • Control
      • Accessories
    • Humidity & CO2
      • Automation system
      • Hygrostats
      • Hygro transducers and hygrothermal transducers
    • Flow
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Measuring devices
      • Controllers
      • Flow sensor
    • Level
      • Automation system
      • Paperless recorders
      • Digital indicators
      • Transmitters
      • Level sensors
      • Level probes
      • Controller
      • Float switches
    • Actuator
      • Semiconductor relay
      • Power control
    • Product selector
    • Product list A-Z
  • Applications
    • All applications at a glance
    • Food and beverage
      • Beer production
      • CIP cleaning
    • Water and wastewater
      • Ground water treatment
      • Swimming pool water treatment
      • Cooling water treatment
    • Railway technology
      • Diesel propulsion
      • Chassis technology
      • Climate control
      • Water supply
    • Hydrogen
    • Aquaculture
    • Industrial furnace construction
      • Continuous heat treatment process
      • Discontinuous heat treatment process
    • Heating and air-conditioning technology
      • Air-conditioning technology
      • Heating technology
      • Heat and cold meters
    • Shipbuilding industry
      • Tank ship
      • Water treatment
      • Heating and cooling systems
    • jumo.page.applications.case-study-silo-temperature-monitoring
  • Services
    • Download center
    • Product archive
    • Frequently asked questions
    • JUMO Engineering
    • Special production
      • Electronic modules
      • Specific temperature sensors
    • Commissioning
      • Field service
      • Configuration service
    • Calibration
      • COFRAC Calibration
      • Temperature calibration
      • Pressure calibration
      • Hygrometry calibration
      • On-site calibration
    • Maintenance
      • Spare parts
      • Repair services
      • Returns
      • Technical support
      • Maintenance contracts
    • Trainings
      • Seminars
      • Exclusive trainings
      • Webinars
      • E-Learnings
    • Electronic data exchange
      • BMEcat
      • EPLAN
  • About Us
    • Profile and focus
    • Expertise and strengths
    • Development partnership
    • Success stories
    • Quality standard
    • Locations worldwide
    • Contact
    • Fair dates
    • Management
    • History
    • Career
    • Social responsibility
    • Current topics
      • News
      • Software Newsletter
      • Newsletter
      • Customer magazine
      • Company information
    • Imprint
    • General Terms and Conditions of Delivery and Service
    • Privacy policy
{}
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar
Type 202530

JUMO dTRANS pH 01

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What is to be taken into account when setting a limit value controller?

In configuration level C211- Controller options, set limit value controller for K1 and K2.
C211- 11xx
In configuration level C212 – Controller outputs, ensure that MIN/MAX and NOC/NCC is set.
C212 – xx10
In configuration level C213 – Other outputs I, the alarm monitoring of relays K1 and K2 is activated for the set point values respectively set.
C213 xxx0
In configuration level C214 – Other outputs II, activate the function (limit value controller) set in configuration level C211-11xx.
C214 – xx11
Note: For this, also refer to chapter 14 Configuration level in the operating instructions Type 202530.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An 'ERR' error message appears on the device.

Calibration of the relative cell constant or determination of the temperature coefficient of the medium to be measured was completed with an error. The previous data is saved.
The factory data is displayed (Cell = 100%, ALPH= 2.3).
To remedy the 'ERR' error message, manually change the two parameters using the keyboard (e.g. change by one digit up or down and confirm with the PGM key) or re-calibrate the system.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

An actual value output is required - What is to be taken into account?

Ensure that the device is equipped with the respective analog output. For this purpose, check the type designation of the device.
Refer to chapter 4.1, Type explanation, in the operating instructions.

0.290

Configuration level C213 - Other outputs I is set.
Actual value output 2 is set in configuration level C214 - Other outputs II.
The scaling is set under the parameters SOL and SOH.
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

I cannot change settings in the parameter level and the configuration level.

To be able to carry out settings in the two levels, enter the respective CODE for activation first.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears. Set the respective CODE by pressing the UP/DOWN keys. Press the PGM key to confirm.
The display returns to 0000. Now, the corresponding level (parameter) can be selected. The code has been entered correctly when the decimal point flashes during entry.

 

Function    Code
Unlock the operator level, CAL and manual activation of Hold. 0110
Unlock the operator and parameter level. 0220
Unlock all levels. 0300
start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

Is it possible to change the switching behavior of N/C / N/O?

The setting N/O / N/C for the two contacts K1 and K2 can be changed in the configuration level under point C212 (controller outputs).
Both contacts are factory set to NOC.
NOC: (N/O) The corresponding output is active (closed) as long as the switching condition is fulfilled.
NCC: (N/C) The corresponding output is active (closed) as long as the switching condition is not fulfilled.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

What does Min/Max contact mean?

The configuration level C212 (controller outputs) can be used to change the Min/Max behavior for the two contacts K1 and K2.
MIN contact: The switching condition is fulfilled when the actual value is lower than the set point value.
MAX contact: The switching condition is fulfilled when the actual value exceeds the set point value.

0.2AC


start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to check the correct function (actual value display) of the device and the coax cable?

The Redox value can also be preset with a pH simulator as for the pH measurement. Then the Redox value can be read from a table contained in the simulator operating instructions. If the simulator is not available, it is possible to directly supply voltage to the device input (BNC socket) and, to check the coax cable, to the end of the cable.
The Rd value can be read on the device according to the voltage.
The device should have the factory settings and should not display any error messages.

pH value
Voltage
2 pH +295,8 mV
4 pH +177,48 mV
7 pH 0 mV
10 pH -177,48 mV
10 pH -295,8 mV


0.712

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

How to start the calibration process?

To be able to start calibration, activate the controller.
Start situation > Measuring mode > Repeatedly press the PGM key until CODE appears > Enter 0300 and confirm with PGM > Press the Exit key once > Simultaneously press the PGM + Down key.
A temperature of 25.0 appears in the top (red) display, °C appears in the bottom (green) display, the decimal point in the bottom display flashes.

start portlet menu bar
Display content menu Display portlet menu
end portlet menu bar

JUMO Campus

Discover training opportunities
More

Or send us a message

Contact us and we will answer your questions – whether about basics or specific topics.
Send a message now
CONTACT

JUMO-REGULATION SAS
7 Rue des Drapiers
57075 Metz Cedex 03, France

Phone: +33 3 87 37 53 00
E-Mail: info.fr@jumo.net

  • Imprint
  • Privacy policy
  • General Terms of Business Relations
QUICKLINKS
  • Career
  • JUMO Customer magazine
  • JUMO Campus
  • Stock catalogue
FOLLOW US
YouTubeFacebookLinkedIn
More than Sensors + Automation
Imprint
Privacy policy
General Terms of Business Relations
Complementary Content Deferred Modules
  • ${title}${badge}
${loading}
Deferred Modules